General - AV-6N

  • Standard full/medium heat recovery unit for diesel and gas engine plants
  • For CHP and Combined cycle (steam and/or hot-water) applications
  • Optimized heat surface designs for different engine/fuel types
  • Easy to clean including on-line sootblowing equipment for minimized downtime
  • High efficiency
  • Natural circulation offering operational safety and cost-savings
  • Vibration-considered robust construction
  • Compact shop-assembled module -design with small footprint and low operational weight
  • Easy and fast installation
  • Below design data is typical data with standard execution. Special solutions considered on case-by-case basis
 
Design data

 

Engine output: No limits
Engine fuel type: Light oil, liquid biofuel, heavy fuel oil, natural gas
Exhaust gas flow: No limits
Exhaust gas temp.: Standard up to 530 ºC
Operating steam/water pressure: Standard up to 30 bar
Steam/water temperature: Standard up to 400 ºC
Circulation: Forced or natural
Pinch point: Standard 15 - 20 ºC





General -
AV-4/AQ-2
 
  • Standard HRSG for small gas turbines
  • Smoke tube boiler, natural circulation
  • Horizontal flue gas pass
  • Unfired to medium-fired applications
  • Can be combined with external water tube superheater
  • and economizer sections

 

 

Design data

Gas turbine output: 2 - 8 MWe
Flue gas temperature: < 600 ºC
Exhaust gas flow: Up to 30 kg/s
Steam capacity: 5 - 15 t/h
Operating steam pressure: Max. 25 bar
Steam temperature: Saturated + 50ºC
Circulation: Natural
 

 

 

General - UNEX™ DE1

 

 

 

  • Special HRSG for medium engine sizes
  • For fuel oil heating applications
  • Horizontal water tube boiler, with built-in steam drum
  • Built-in capacity control 
  • Natural circulation
  • Compact design (small footprint)

Design data

 

 
Diesel engine output: 0.5 - 20 MWe
Engine fuel type: LFO, HFO
Exhaust gas flow: Up to 30 kg/s
Exhaust gas temperature: < 500 ºC
Steam capacity: up to ~5 t/h
Operating steam pressure: 4 - 15 bar
Steam temperature: Saturated


General - AV-6N GE

  • Standard horizontal full/medium heat recovery unit for gas engine plants
  • For CHP (hot-water) applications
  • High efficiency
  • Vibration-considered robust construction
  • Compact shop-assembled module -design with small footprint and low operational weight
  • Easy and fast installation
  • Below design data is typical data with standard execution
  • Special solutions considered on case-by-case basis

Design data

 

Diesel engine output: No limits
Diesel engine fuel type: Light oil, Natural gas, Heavy fuel oil
Exhaust gas flow: No limits
Exhaust gas temperature: < 500 ºC
Operating pressure: Standard 5 - 30 bar
Steam temperature: Standard up to 400 ºC
Circulation: Forced
Pinch point: Standard 15 - 20 ºC, min. 5 ºC limited by feasibility only